Success: Horizontal natural gas separator/scrubber

Jul 12, 2021 | Compressed Air/Gas, Contamination, Fuel Oil & Natural Gas

  1. Home
  2. Contamination
  3. Success: Horizontal natural gas separator/scrubber

Horizontal filter vessel for natural gasWe recently worked with a natural gas company in the midwest that had some underground storage facilities and a compressor station that had a problem with sludge. They believed that the contaminants were iron sulfide and compressor oil. To help them solve their problem we provided them with a new horizontal separator/scrubber to utilize in their pigging operations. This vessel was rated for 750 PSIG @ 120° F and can handle a gas flow rate of 2,500-4,500 MMSCFH. It included a 304 stainless steel vane/mesh pad and a 20” 600# manway flange that they could use for cleaning and removal of the sludge. The liquid removal efficiency was 99% ≥ 10µm. Although our account here is brief, there were many hands that went into the achievement of this success story. We are grateful to have such a talented team.

Do you have any questions? Feel free to contact us and ask to speak with either of us directly.

— John, Inside Sales
— Bill, Technical Sales

Contact an Expert

Need assistance? PFP will help you solve your industrial filtration challenges.

1-888-679-6645 / sales@pfpusa.com

Related Blog Posts

How Often Should Generator Fuel Be Tested?

How Often Should Generator Fuel Be Tested?

Drop us a follow on social media!TL;DR - Generator fuel should be tested at least once per year to check for water, microbial growth, and particulate contamination. Critical facilities like hospitals and data centers often test every 6 months or quarterly to ensure...

Lube Oil Contamination: Vacuum Dehydrator Rental Solutions

Lube Oil Contamination: Vacuum Dehydrator Rental Solutions

Lube Oil Contamination SolutionsThis case study explains how PFP mobilized a vacuum dehydrator rental within 24 hours to address water and particulate contamination in a paper mill lube oil reservoir.Recently, we were contacted by a manufacturer in the paper industry...

HIAC PODS Discontinued: Replacement Options

HIAC PODS Discontinued: Replacement Options

We offer a variety of replacement options for Beckman Coulter's discontinued HIAC PODS Particle Counter.If you landed here looking for a Beckman Coulter HIAC PODS recalibration, rental, or purchase option, you're not alone. We hear from customers all the time who...

Follow us on social media!

Contact an Expert

Need assistance? PFP will help you solve your industrial filtration challenges.

1-888-679-6645 / sales@pfpusa.com

Want the most up to date information from PFP?

Sign up for our E-mail newsletter!